• Home
  • Global Directory
  • Contact
  • Official S&P Youtube channel
  • Official S&P Flickr Photostream
  • Share:
    CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS
    CADB/T-HE PRO-REG Series

    CADB-T-HE-PRO-REG

    Compact heat recovery unit with high-efficiency (up to 93%) counter-flow heat exchanger, EUROVENT certified. The casing is made from plasticised galvanised steel in white. Panels are double skinned with thermo-acoustic flameproof insulation (M0), made from 25mm thick fiberglass, 25mm thickness in false ceiling versions (Models 04 to 21 ) and 50mm in Outdoor versions (Models 40 and 54).

    Configurable and airtight supply and exhaust spigots, suitable for horizontal installation.

    Applications
    Commercial premises, offices, restaurants, public buildings, schools.

    CADB/T-HE D PRO-REG
    Heat recovery units without additional incorporated heater.

    CADB/T-HE DI PRO-REG
    Heat recovery units with built-in electric heater battery.

    CADB/T-HE DC PRO-REG
    Heat recovery units with built-in low pressure hot water coil.

    The 3-Way valve is provided as an accessory (see accessories table for this series)

    Motors
    Models 04 to 21: EC motors with integrated electronic protection, IP44, Class B.
    Models 40 and 54: Three phase motors, IP55,Class F.

    Fans
    Plug-fan with backward curved impeller.
    All fans installed in CADB/T- HE PRO-REG models, comply with the efficiency requirements of the ErP Directive.

    Filters
    - F7: Low pressure F7 filters for supply air.
    -M5: M5 filters for extract air.

    Control
    It includes manual or automatic control for modes: adjustable airflow (VAV), constant pressure (COP) or constant airflow (CAV), via CO2, pressure or airflow sensors (accessories).
    Post-heating stage versions (-DI/-DC) allow post-heating management depending on the temperatures taken by the temperature probes incorporated in the design.

    Ranges of product according to the type of operating control:
    VAV- variable air volume
    Fan speed can be adjusted with a 0 - 10V signal from the remote touchscreen panel (included) or an external CO2, temperature or humidity sensor (accessories).
    CAV - constant air volume
    Manual pre-setting of 2 working points the fans are controlled separately. It is necessary to add two pressure sensors TDP-D as external accessory.
    COP - constant pressure
    Constant pressure measured by an external pressure sensor TDP-S (accessory). It is necessary to add a pressure sensor TDP-S as an external accessory*.
    * To control supply and extract air separately it is necessary to install 2 pressure sensors TDP-S.

    Additional information
    Single phase (CADB-HE PRO-REG) and three phase models (CADT-HE PRO-REG). Airflows from 400 to 5400 m3/h at 150 Pa of static pressure available.
    All versions and models include by-pass. Mounting flexibility provided by the interchangeable side panels.
    CADB-T-HE-PRO-REG

    More Views

    FILTERS

    HORIZONTAL CONFIGURATION

    WITHOUT ADDITIONAL HEAT

    ELECTRIC BATTERY INCLUDED

    WATER COIL INCLUDED

    Remote control panel
    Maximum wire distance 50 m.
    Connection wire not included.

    Security switch
    All versions include a On/Off security device.

    Low noise level and robust construction
    Casing with double skinned 25 mm panels with thermoacoustic flameproof insulation M0, with high-quality finish and plastic corners.

    PRO-REG Controller
    Mounted in an IP54 weatherproof electrical box.

    High-efficiency motors
    Incorporating Plug-fans with EC single-phase motor.

    Bypass
    All versions include internal bypass (approximately 75% airflow).

    Counterflow heat exchanger
    high-efficiency (up to 93%), EUROVENT certified.

    High-efficiency filters
    -F7 Filters: Low pressure F7 filters for supply air.
    -M5 Filters: M5 filters for extract air. Possibility of mounting a second filter (accessory).

    Support
    Specific supports to allow installation in false ceilings via threaded rods.